Fuel contents transmitters

Variable length type
:
For uniform section rectangular or circular tanks with 6-hole flange fixing
(For gauges with bi-metal characteristics, a voltage stabiliser is required)
PRODUCT CODE
DESCRIPTION
TB9010/Kit
Top mounted, earth return  - "Euro" characteristics
TB9011/Kit
Top mounted, insulated return - "Bi-metal" characteristics
TB9012/Kit
Top mounted, insulated return - "Euro" characteristics
TB9013/Kit
Side mounted, insulated return - "Bi-metal" characteristics
TB9014/Kit
Side mounted, insulated return - "Euro" characteristics
TB9018/Kit
Side mounted, earth return - "Euro" characteristics
TB9006/Kit
Top mounted, warning light - "Bi-metal" characteristics
Side and End Mounting - Rectangular Tank
Tank
Depth (mm)

Arm Length
(mm)

Tank
Depth (mm)

Arm Length
(mm)

Bi-Metal
Euro
Bi-Metal
Euro
610
338
310
432
249
228
584
325
298
406
236
216
559
312
286
381
223
205
533
299
275
356
-
193
508
287
263
330
-
181
483
274
252
305
-
170
457
261
240
279
-
158
Side and End Mounting - Cylindrical Tank
Tank
Depth (mm)

Arm Length
(mm)

Tank
Depth (mm)

Arm Length
(mm)

Bi-Metal
Euro
Bi-Metal
Euro
610
283
260
381
189
173
584
272
250
356
179
164
559
262
240
330
168
154
533
251
230
305
158
145
508
241
221
279
147
135
483
231
212
254
137
126
457
220
202
229
126
-
432
210
193
203
-
-
406
199
183
-
-
-
Top Mounting - Rectangular Tank
Tank
Depth (mm)

Arm Length
(mm)

Tank
Depth (mm)

Arm Length
(mm)

Bi-Metal
Euro
Bi-Metal
Euro
610
542
494
381
316
288
584
517
471
356
292
266
559
492
449
330
266
243
533
466
425
305
241
220
508
442
403
279
216
197
483
417
380
254
191
174
457
391
357
229
165
152
432
367
334
203
141
128
406
341
311
-
-
-
Terms & Conditions
General Fitting Instructions
Measure internal depth/diameter of the fuel tank
1
2
3
Assemble the wire arms and clips as shown in the diagram to give the specified length
Select arm length required against tank depth measured, from appropriate table
9
8
7
6
5
4
Trim excess wire retaining maximum overlap to maintain rigidity
Ensure that the float axis is parallel to the tank unit flange
Coat both sides of gasket with sealant and assemble tank unit to tank flange
Secure firmly and evenly
Solder at and around the two clips, guard against over-heating
Fit the float to the end of the arm, either way round is acceptable
NOTE: Interpolation between max and min listed values only is permissible, using the nearest listed value to that measured
Terms & Conditions